Charactersitics cNPP aNPP
Number of reactor units 1 4
Rated power level per reactor unit [MWe] 360 90
Fuel inventory per reactor unit* \(x\) \(\sim x/4\)
Integral reactor vessel layout no yes
Aspect ratio \(< 2\) \(3 \div 4\)
Construction of the reactor building above-grade below-grade
Modularity absent good
Fully met FRs / 1, 2, 3, 4, 5, 6, 7
Partially met FRs 1 /
Unmet FRs 2, 3, 4, 5, 6, 7 /